L63-RM1-PMR-SERVICE-ANALYSER-COAL-MILL
Wahyu Adi TrionoProblem: Clean up sample line, flange, filter probe, filter balston, membran pump, check filter humidity
Action:
Flange for L63 3K3, L63 2K2 very dirty many wet coal inside and sample line also dirty..add for clean fikter probe outside romm 483 2K1
Status: done